Abstract

Although many publications on the subject are available, only few campaigns for stethoscopes cleaning and disinfection are conducted. Stethoscope is a "not critical" reusable medical device and should benefit from a cleaning disinfection "low level" after each use. We studied the bacterial contamination of stethoscopes in our hospital and measured the role of bacterial reservoir and/or vector stethoscope could play. Mean microbial load was estimated at 1.550 CFU per stethoscope. Results obtained in our hospital and those of the literature, led us to propose a simple and efficient cleaning method. We believe motivate everyone to change their habits and carry out disinfection more frequent their very handling stethoscope.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.