Abstract

The operation of backilluminated ultraviolet (UV) photodetector based on GaN/Al0.27Ga0.73N multiple quantum wells (MQWs) is reported. The MQW structure was deposited on a 1-μm-thick Al0.35Ga0.65N buffer layer which was epitaxied on a sapphire substrate. Coplanar Ohmic contacts were made on the top side of the MQW structure. By illuminating the Ohmic contact positions from the backside of the detector, a flat and narrow band spectral response is achieved in the UV wavelength range from 297 nm to 352 nm. The electron-heavy hole absorption in the MQW region produces the sharp long-wavelength cutoff at 352 nm and the band-to-band absorption of the Al0.35Ga0.65N buffer layer introduces the sharp short-wavelength cutoff at 297 nm. The polarization-induced electric fields result in a redshift of the long-wavelength cutoff. The response time is measured to be RC limited and determined to be 5 μs at a 50 Ω load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.