Abstract

To introduce a scout view scanning technique of back-forward bending CT (BFB-CT) in simulated surgical position for evaluating the remaining real angle and flexibility of thoracolumbar kyphosis secondary to old osteoporotic vertebral compression fracture. A total of 28 patients with thoracolumbar kyphosis secondary to old osteoporotic vertebral compression fracture who met the selection criteria between June 2018 and December 2021 were included in the study. There were 6 males and 22 females with an average age of 69.5 years (range, 56-92 years). The injured vertebra were located at T 10-L 2, including 11 cases of single thoracic fracture, 11 cases of single lumbar fracture, and 6 cases of multiple thoracolumbar fractures. The disease duration ranged from 3 weeks to 36 months, with a median of 5 months. All patients received examinations of BFB-CT and standing lateral full-spine X-ray (SLFSX). The thoracic kyphosis (TK), thoracolumbar kyphosis (TLK), local kyphosis of injured vertebra (LKIV), lumbar lordosis (LL), and the sagittal vertical axis (SVA) were measured. Referring to the calculation method of scoliosis flexibility, the kyphosis flexibility of thoracic, thoracolumbar, and injured vertebra were calculated respectively. The sagittal parameters measured by the two methods were compared, and the correlation of the parameters measured by the two methods was analyzed by Pearson correlation. Except LL ( P>0.05), TK, TLK, LKIV, and SVA measured by BFB-CT were significantly lower than those measured by SLFSX ( P<0.05). The flexibilities of thoracic, thoracolumbar, and injured vertebra were 34.1%±18.8%, 36.2%±13.8%, and 39.3%±18.6%, respectively. Correlation analysis showed that the sagittal parameters measured by the two methods were positively correlated ( P<0.001), and the correlation coefficients of TK, TLK, LKIV, and SVA were 0.900, 0.730, 0.700, and 0.680, respectively. Thoracolumbar kyphosis secondary to old osteoporotic vertebral compression fracture shows an excellent flexibility and BFB-CT in simulated surgical position can obtain the remaining real angle which need to be corrected surgically.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.