Abstract
Many studies have shown that pulsed air jet has a high removal power with little air consumptions. The purpose of this study was to elucidate dust removal mechanism of pulsed air. This paper presents measurement results obtained on the wall pressure measurement and the air consumption measurement. Measurement results of the wall pressure measurement show the most efficient removal condition is duty factor 40% at frequency 5[Hz]. In the air consumption measurement, as compared with normal air jet, the condition have realized a 56% reduction of air consumptions. In the particle removal experiment, all conditions have high removal rate. The results show the particle removal rate and the air consumption are independent. Here we have confirmed the pulsed air is a technique that can reduce air consumption.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the Symposium on the Motion and Vibration Control
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.