Abstract
Abstract Background Androstenedione and 17-hydroxyprogesterone are measured via immunoassays or high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) in clinical laboratories. Immunoassays have limited sensitivity and specificity for certain steroid hormones testing. We aimed to develop and validate a sensitive, accurate, and specific in-house LC-MS/MS assay to simultaneously measure both 17-hydroxyprogesterone and androstenedione in serum. Methods 13C-labeled androstenedione and 17-hydroxyprogesterone internal standards were added to calibrator, control, and patient samples. A hexane/ethyl acetate solution was used in a liquid-liquid extraction procedure. The organic layer was then removed and dried followed by reconstituting the extracts in 2.5 mM ammonium formate in 50% methanol. The HPLC mobile phase gradient began with 47%, 2.5 mM ammonium formate in water and 53%, 2.5 mM ammonium formate in methanol. This progressed to 56% of the methanol phase over three minutes. The mixtures were separated though an Agilent 1260 Infinity HPLC system with a Poroshell 120 EC-C18 analytical column (2.1 × 50 mm × 2.7 µm). The separated HPLC eluents then entered an Agilent 6460C QQQ mass spectrometer in positive ion mode through an electrospray ionization source where protonated androstenedione (m/z = 287.2) with the protonated androstenedione-[2, 3, 4-13C3] internal standard (m/z = 290.2) and protonated 17-hydroxyprogesterone (m/z = 331.2) with the protonated 17-hydroxyprogesterone-[2, 3, 4-13C3] (m/z = 334.2) were mass-selected for collision-induced dissociation. For androstenedione, respective quantifier and qualifier m/z values of 287.2 > 97.1 and 287.2 > 109.1 were used while respective quantifier and qualifier m/z values of 331.2 > 97.1 and 331.2 > 109.1 were used for 17-hydroxyprogesterone. Validation studies were performed including imprecision, lower limit of quantitation (LLOQ), analytical measurement range (AMR), interference, specificity, carryover, extraction recovery, matrix effect, and comparison with a reference laboratory LC-MS/MS method. The total allowable error limits used in this study were 23.5% for androstenedione and 30.2% for 17-hydroxyprogesterone. Results Total imprecision results across three concentrations yielded a maximum CV of 4.6 % for androstenedione and 6.5% for 17-hydroxyprogesteron. The AMRs of androstenedione and 17-hydroxyprogesterone were 0.2 to 13.4 and 0.1 to 22.0 ng/mL without significant carryovers. No significant interferences were observed from 11-deoxycorticosterone (700 ng/dL), testosterone (2500 ng/dL), DHEA (1000 ng/mL), bilirubin (30.1 mg/dL), hemoglobin (1032 mg/dL), or triglycerides (1858 mg/dL). The extraction recoveries of androstenedione and 17-hydroxyprogesterone were 98% and 81%, respectively. No significant matrix effects were identified. In comparison to the reference lab LC-MS/MS method, the in-house LC-MS/MS assay demonstrated a 0.523% bias for androstenedione and a -3.77% bias for 17-hydroxyprogesterone with both exhibiting excellent correlations with the reference lab measurements. More specifically, our results (as a function of values obtained from the reference lab) followed the relationship of y = 1.039x - 0.092 (R = 0.9951) for androstenedione and y = 0.957x + 0.01 (R = 0.9974) for 17-hydroxyprogesterone. Conclusions An LC-MS/MS assay is developed for simultaneous detection of serum androstenedione and 17-hydroxyprogesterone. The assay demonstrates acceptable imprecision, AMR, and accuracy. No significant carryover and interference from other structurally similar steroid hormones and other common interferents are identified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.