Abstract

Cannulation of central veins and placement of catheters for temporary haemodialysis is a common procedure in the management of patients with end stage renal failure. The internal jugular vein is the site of choice for central venous catheter placement, being associated with the lowest complication rate. This procedure can be associated with a variety of malpositions of the catheter and rarely, can lead to significant morbidity and even mortality, if this is not recognised and corrected early. For anatomical reasons, the risk of azygos arch cannulation is substantially increased if catheters are inserted via left-sided veins. We report a case with a rare complication associated with the insertion of a catheter for temporary haemodialysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.