Axially varying vapor superheats in convective film boiling have been measured for water flowing in a vertical tube at low to moderate pressures and mass flow rates. Using a slow “reflood” process, measurements of wall temperature and nonequilibrium vapor temperature were obtained as functions of distance from the quench front. With the low quench front velocity, the time required to progapate the front a few millimeters corresponds to many fluid residence times, and the thermal hydraulic data thus obtained are quasi-steady state. These experimental results indicate a zone near the quench front where the vapor generation rate is relatively high, followed by a far zone where the generation rate drops off to a relatively low magnitude. The data obtained agree with the very limited previously reported steady-state data. Comparison with existing heat transfer models shows the models give poor predictions of vapor superheats but reasonable predictions of wall heat fluxes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.