Abstract

Axial tensile moduli, compressive moduli and compressive strengths of rigid-rod poly( p-phenylene benzobisoxazole) and stiff-chain poly( p-phenylene terephthalamide), Kevlar™, fibres were measured with a Tecam Micro-tensile Testing Machine. This machine was configured to allow for testing of single fibres in direct tension and compression at extremely small gauge lengths. The appropriate gauge lengths were estimated based on the discussion of Euler buckling and non-uniform stress distribution in anisotropic materials. The measured tensile and compressive moduli were analysed for corrections to machine compliance and possible gauge length error. The corrected compressive moduli were slightly lower than the corrected tensile moduli, probably due to fibre misalignment under compression and the fibrillar nature of the fibres. The fibre axial compressive strengths measured by direct compression were comparable to those measured from recoil and composite tests but lower than those from cantilever beam and elastica loop tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.