Abstract
As a novel inner surface processing method, grid enhanced plasma source ion implantation (GEPSII) method can realize uniform inner surface ion implantation of a metal tube and metal binary compound can be produced. In the experiment, three 0.45% carbon steel (45-steel) work pieces were axially put on the inner surface of the tube, and golden titanium nitride (TiN) films were produced on the work pieces by GPSII. Structure analysis shows that the TiN films have the preferred crystal faces (111) and (200), and the depth of the films is about 20 nm with partial embedding in the substrate. Analysis on the electrochemistry corrosion, hardness and friction of the work pieces indicates that the surface property of the 45-steel has been greatly improved by the protective TiN film, and very good axial uniformity has been obtained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.