Abstract

Axial displacement of the stator in a synchronous machine gives rise to axial magnetic field both at the ends and deep inside the stator. The axial magnetic field causes losses. This article contains results from two studies with an axially displaced stator. In the first study, axial magnetic leakage fields in the ends of a small synchronous generator at load and no load were measured and simulated. In the second study, axial force and iron losses at no load were calculated with non-linear materials and a three-dimensional, time-stepped finite element method. For some machines with vertical shafts, the sum of iron losses and thrust bearing losses can be reduced if the rotor is lowered or the stator raised, whichever is best.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.