In this paper, empirical formulae were developed between the well-known pile bearing capacity factors (Nqand β) and parameters which include friction angle of sand, relative density, average effective vertical stress, and deformability of the soil below the pile toe. The developed empirical formulae were totally based on a database comprised of 28 well-documented compressive pile load tests collected exclusively from geotechnical literature. The actual measurements of shaft and end-bearing resistances of each pile in the database were adjusted to account for post-driving residual loads. Calculation of pile bearing capacity factors (Nqand β) was based on the adjusted shaft and end-bearing resistances rather than the actual unadjusted measured resistances for residual loads. Comparison of predicted and measured compressive capacity of an independent database comprised of 18 pile load tests showed that the developed formulae yield a reasonably accurate estimate of compressive pile capacity in cohesionless soils.Key words: driven piles, residual load, toe resistance, shaft resistance.