Abstract

The axial compressive behaviour of an innovative type of square concrete filled steel tube (CFST) column to reinforced concrete (RC) beam joint was experimentally investigated in this paper. The innovative joint was designed such that (i) the steel tubes of the CFST columns were completely interrupted in the joint region, (ii) the longitudinal reinforcements from the RC beams could easily pass through the joint area and (iii) a reinforcement cage, including a series of reinforcement meshes and radial stirrups, was arranged in the joint area to strengthen the mechanical performance of the joint. A two-stage experimental study was conducted to investigate the behaviour of the innovative joint under axial compression loads, where the first stage of the tests included three full-scale innovative joint specimens subjected to axial compression to assess the feasibility of the joint detailing and propose measures to further improve its axial compressive behaviour, and the second stage of the tests involved 14 innovative joint specimens with the improved detailing to study the effect of the geometric size of the joint, concrete strength and volume ratio of the steel meshes on the bearing strengths of the joints. It was generally found from the experiments that (i) the innovative joint is capable of achieving the design criterion of the ‘strong joint-weak member’ with appropriate designs, and (ii) by decreasing the height factor and increasing the volume ratio of the steel meshes, the axial compressive strengths of the joints significantly increased, while the increase of the length factor is advantageous but limited to the resistances of the joint specimens. Because of the lack of existing design methods for the innovative joints, new design expressions were proposed to calculate the axial compression resistances of the innovative joints subjected to bearing loads, with the local compression effect, the confinement effect provided by the multi-layers of steel meshes and the height effect of concrete considered. It was found that the proposed design methods were capable of providing accurate and safe resistance predictions for the innovative joints.

Highlights

  • The concrete-filled steel tube (CFST) structure is a high-efficiency solution for high-rise buildings and bridges due to its high bearing capacity, excellent ductility and great energy dissipation capacity [1].Materials 2020, 13, 2482; doi:10.3390/ma13112482 www.mdpi.com/journal/materialsIn concrete filled steel tube (CFST) structures, the joints connecting the CFST columns and reinforced concrete (RC) beams play an important role in achieving the structural integrity of the CFST frame [2,3], and researches related to the detailing of the joints have become a hot spot during the past few years

  • Nie et al [8] and Bai et al [9] developed a representative through-beam joint connecting the concrete encased CFST columns and RC beams, where the steel tubes of the CFST columns were completely interrupted in the joint area, and the steel-reinforcement bars in the RC beams were continuous in the floor

  • The dilation and local buckling of the steel tubes were observed when the specimens reached their peak loads, while the concrete in the joint area remained observed when the specimens reached their peak loads, while the concrete in the joint area remained intact without series spalling, which indicates that the specimens were failed by the local buckling of outer steel tubes of the CFST columns and satisfied the design criterion of the ‘strong joint-weak member’

Read more

Summary

Introduction

The concrete-filled steel tube (CFST) structure is a high-efficiency solution for high-rise buildings and bridges due to its high bearing capacity, excellent ductility and great energy dissipation capacity [1]. Nie et al [8] and Bai et al [9] developed a representative through-beam joint connecting the concrete encased CFST columns and RC beams, where the steel tubes of the CFST columns were completely interrupted in the joint area, and the steel-reinforcement bars in the RC beams were continuous in the floor. Provided that the steel tubes of the CFST columns were generally interrupted at the joint area, axial compressive tests on the through-beam joints were conducted by Nie et al [8], Bai et al [9], Chen et al [11] and Zhou et al [13], to investigate the axial compressive strengths of the joints; it was found that the strengths of the joints were higher than those of the corresponding CFST columns, and the design criterion of the ‘strong joint-weak member’.

General
Details
Experimental
Results
Load-Deformation and Load-Strain
Load-strain for steel meshes at plan positions in specimen
Summary for the Series I Tests ε
Summary for the Series I Tests
Failure
13. Test setup
Load-Deformation Curves and Load-Strain Curves
Summary for for the the Series
Effect of Local Compression
Confinement Effect Provided by the Multi-Layers of Steel Meshes
Height Effect of Concrete
Predictionofand
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call