Abstract

Zeta potential and avidin adsorption of silicone elastomer (SE) and SE coated with polyethyleneimine (PEI) and heparin is studied under controlled hydrodynamic conditions. Zeta potential (ζ) of SE depends on the duration of contact with buffer (0.02M MOPS–KCl, pH 7.2): ζ descends from 12mV to a plateau value of −32mV during 5h and decreases further if SE is stretched (30% elongation). The time variation of ζ is attributed to surface charging of the core polymer PDMS. Coating the negatively charged SE with PEI results in ζ=42mV; a layer of heparin on top of PEI yields ζ=−46mV. On the negatively charged surfaces, avidin adsorption levels off at 5mV. Desorption of avidin from SE is negligible even when SE with adsorbed avidin is stretched, or when the stretching force is removed after adsorption of avidin. The results can be employed for designing biomaterials with properties such as surface charge and protein adsorption adjustable by stretching; the strong attachment of avidin can allow for further surface modification.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call