Abstract

Currently the majority of radiotherapy treatments are done by irradiation with high energy photon beams. These beams are emitted by radioactive sources (of nuclides such as cobalt 60) or generated in electron linear accelerators. For dosimetric measurements on these beams, one of the most used techniques is the thermoluminescence (TL). For the correct use of the thermoluminescent dosimeters (TLDs), it is necessary to know their dosimetric properties like, for example, the variation of their response with the energy of the radiation beam. The purpose of this study was to assess the energy response of various TL materials when irradiated with high energy photon beams. So, curves relating the TL response and absorbed dose to water were obtained for LiF:Mg, Ti (TLD-100), Brazilian natural fluorite, CaSO4:Dy, Mg2SiO4:Tb and Al2O3:C TLDs irradiated with gamma rays from a Co source and linear accelerator X ray beams with nominal accelerating potential of 6, 10, 15 and 18 MV. The study was done in a dose range similar to that used in standard fractionated radiotherapy treatments and the results show that under these conditions, there is no variation larger than 3% in the TL response as a function of photon energy. The relationship between the dose deposition in the TLD and the dose deposition in water in function of the photon energy was studied by Monte Carlo method (MC), using the PENELOPE code system, and the results were consistent with the experimental outcomes. The TLDs were also irradiated with thermal and epithermal neutrons and proved to be sensitive to them. However, the consistency of the experimental and MC results (which did not take into account the presence of neutrons), the study of the variation in TL relative sensitivity with the beam energy, and the TLD glow curve shape analysis lead to the conclusion that the influence on TL response due to neutron contamination in the therapeutic photon beams is negligible for all materials. The results indicate that for the range of doses and energies used routinely in radiotherapy, the LiF:Mg, Ti (TLD-100), Brazilian natural fluorite, CaSO4:Dy, Mg2SiO4:Tb and Al2O3:C TLDs can be used without applying any correction factors for the beam energy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.