Detailed availability statistics, and reliability statistics in terms of trip rates, between 1994 and 2021 at the ISIS Spallation Neutron Source are presented. The average of the availabilities for 121 irradiation campaigns spanning the better part of three decades is 86% with a standard deviation of 7%. Trip rates at ISIS are very similar to trip rates at high-power proton machines of different accelerator ‘architecture’ elsewhere, and altogether these trip rates can be fitted quite well over several orders of magnitude by the simple power law Ṅ=6t−0.75 where Ṅ is the number of trips per day longer than time t (t in minutes). Typical trip rates for present-day accelerator systems would appear to be too high to be suitable for acceptable operation of accelerator-driven subcritical reactor systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.