Abstract
The aim of the work is to improve the power conversion efficiency of a voltage-source three-phase inverter with a single active auxiliary resonant DC link snubber circuit (ARDCL). The operating principle and salient features of the ARDCL snubber circuit are described. An effective space voltage vector generation method is of proposed zero voltage vector of a three-phase soft-switching inverter, which can reduce power losses in the ARDCL snubber circuit. The zero voltage holding interval in the DC bus-line of the three-phase inverter is controlled due to the generation method of the zero voltage vector. The feasible experimental results confirm the relationship between the inverter power conversion efficiency and the proposed zero voltage vector generation method is concretely implemented and evaluated from a practical point of view.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.