Abstract

BackgroundThe Manchester Triage System is commonly used as the triage system in emergency departments of the UK. As per the Manchester Triage System, patients presenting with retention of urine to the accident and emergency department are categorized to yellow, which denotes that the ideal maximum time to first contact with a treating clinician will be 60 min. Cervical spinal cord injury patients, in whom urinary catheter is blocked, may develop suddenly headache, sweating, high blood pressure, cardiac dysrhythmia, convulsions, intracranial bleed, and acute neurogenic pulmonary oedema as a result of autonomic dysreflexia due to a distended bladder.Case presentationA 46-year-old male with C-6 tetraplegia developed urinary retention because of a blocked catheter. He was seen immediately on arrival in the spinal injuries unit. The blocked catheter was removed and a new catheter was about to be inserted. Then this patient said that the ceiling lights were very bright and glaring. Five milligrams of Nifedipine was given sublingually. This patient started having fits involving his head, face, neck and shoulders with loss of consciousness. A 14-French silicone Foley catheter was inserted per urethra without any delay and 300 ml of clear urine was drained. This patient recovered consciousness within 5 min. Computed tomography of the brain revealed no focal cerebral or cerebellar abnormality. There was no intra-cranial haemorrhage.ConclusionThis case illustrates that spinal cord injury patients with lesion above T-6, who develop retention of urine because of a blocked catheter, may look apparently well, but these patients can develop suddenly life-threatening autonomic dysreflexia. Therefore, spinal cord injury patients, who present to the accident and emergency department or spinal units with a blocked urinary catheter, should be seen urgently although their vital signs may be stable on arrival. Increasing the awareness of staff in emergency departments regarding autonomic dysreflexia as well as education of the patient and carers will be useful in preventing this complication in persons with spinal cord injury.

Highlights

  • The Manchester Triage System is commonly used as the triage system in emergency departments of the UK

  • This case illustrates that spinal cord injury patients with lesion above T-6, who develop retention of urine because of a blocked catheter, may look apparently well, but these patients can develop suddenly lifethreatening autonomic dysreflexia

  • Spinal cord injury patients, who present to the accident and emergency department or spinal units with a blocked urinary catheter, should be seen urgently their vital signs may be stable on arrival

Read more

Summary

Conclusion

This case illustrates that spinal cord injury patients with a lesion above T-6, who develop retention of urine because of a blocked catheter, may look apparently well, but these patients can suddenly develop life-threatening autonomic dysreflexia manifested by pounding headache, high blood pressure, cardiac dysrhythmia, convulsions, intra-cranial bleed, and acute neurogenic pulmonary oedema. Spinal cord injury patients with a lesion above T-6 who present to the accident and emergency department or spinal injuries units with a blocked urinary catheter should be seen urgently their vital signs may be stable on arrival. Consent Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal

Background
Discussion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.