Abstract

BackgroundGiven the increasing number of people suffering from tinnitus, the accurate categorization of patients with actionable reports is attractive in assisting clinical decision making. However, this process requires experienced physicians and significant human labor. Natural language processing (NLP) has shown great potential in big data analytics of medical texts; yet, its application to domain-specific analysis of radiology reports is limited.ObjectiveThe aim of this study is to propose a novel approach in classifying actionable radiology reports of tinnitus patients using bidirectional encoder representations from transformer BERT-based models and evaluate the benefits of in domain pre-training (IDPT) along with a sequence adaptation strategy.MethodsA total of 5864 temporal bone computed tomography(CT) reports are labeled by two experienced radiologists as follows: (1) normal findings without notable lesions; (2) notable lesions but uncorrelated to tinnitus; and (3) at least one lesion considered as potential cause of tinnitus. We then constructed a framework consisting of deep learning (DL) neural networks and self-supervised BERT models. A tinnitus domain-specific corpus is used to pre-train the BERT model to further improve its embedding weights. In addition, we conducted an experiment to evaluate multiple groups of max sequence length settings in BERT to reduce the excessive quantity of calculations. After a comprehensive comparison of all metrics, we determined the most promising approach through the performance comparison of F1-scores and AUC values.ResultsIn the first experiment, the BERT finetune model achieved a more promising result (AUC-0.868, F1-0.760) compared with that of the Word2Vec-based models(AUC-0.767, F1-0.733) on validation data. In the second experiment, the BERT in-domain pre-training model (AUC-0.948, F1-0.841) performed significantly better than the BERT based model(AUC-0.868, F1-0.760). Additionally, in the variants of BERT fine-tuning models, Mengzi achieved the highest AUC of 0.878 (F1-0.764). Finally, we found that the BERT max-sequence-length of 128 tokens achieved an AUC of 0.866 (F1-0.736), which is almost equal to the BERT max-sequence-length of 512 tokens (AUC-0.868,F1-0.760).ConclusionIn conclusion, we developed a reliable BERT-based framework for tinnitus diagnosis from Chinese radiology reports, along with a sequence adaptation strategy to reduce computational resources while maintaining accuracy. The findings could provide a reference for NLP development in Chinese radiology reports.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call