Abstract

Abstract Funding Acknowledgements Type of funding sources: Public Institution(s). Main funding source(s): Norwegian University of Science and Technology. Background Left ventricular (LV) volumes and ejection fraction (EF) are the most used and studied parameters in echocardiography, but they are hampered with the tedious nature and limited reproducibility of manual measurements. We developed an artificial intelligence (AI) decision-support software that automatically calculates LV volumes and EF by identifying the view, timing, and endocardial border from echo images. Purpose Our aim was to investigate the impact of using the AI decision-support software for automatic measurements of LV volumes and EF compared to standard care in real-time and large databases. Methods We compared biplane three-cycle averaged AI measurements of LV volumes and EF to manual references in multiple samples: 1) Real-time AI-support during scanning of 50 consecutive patients compared to standard care (test-retest) by two of three experts, 2) comparison of test-retest variability in inter- and intra-observer scenarios in 40 subjects with test-retest datasets by separate observers and measurements by AI and four experienced observers, 3) an internal database of 1881 subjects with manual references by Simpson’s method, and 4) an external population of 849 subjects with manual references by semi-automatic tracking-based software. The influence on time consumption was tested in Sample 1. The influence on test-retest variability was tested in Sample 1 and 2, while the other samples were used to test the agreement with echocardiographic references. Results Used in real-time the AI measurements reduced total time-consumption by median (95% CI) 5.3 (4.8–6.5) minutes per patient (p <0.001). The test-retest variability for AI-measurements were superior to inter-observer scenarios (p <0.05) and non-inferior to intra-observer scenarios (p <0.025, one-sided, delta=46% increased variance). The agreement with echocardiographic references was good (Figure). The biases (AI minus reference) ranged −11.6 to 6.5 mL for end-diastolic LV volume and −5.5 to 0.3 %-points for EF. Conclusion Fully automatic AI measurements of LV volumes and EF reduced time-consumption with 5 minutes, reduced test-retest variability compared to inter-observer analyses, and showed acceptable agreement with manual measurements in a wide range of scenarios. Thus, implementation of real-time fully automatic measurements of LV volumes and EF during scanning may improve the everyday workflow and quality in the everyday clinic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.