Abstract
Fluoroscopy guided interventions (FGIs) pose a risk of prolonged radiation exposure; personalized patient dosimetry is necessary to improve patient safety during these procedures. However, current FGIs systems do not capture the precise exposure regions of the patient, making it challenging to perform patient-procedure-specific dosimetry. Thus, there is a pressing need to develop approaches to extract and use this information to enable personalized radiation dosimetry for interventional procedures. To propose a deep learning (DL) approach for the automatic localization of 3D anatomical landmarks on randomly collimated and magnified 2D head fluoroscopy images. The model was developed with datasets comprising 800000 pseudo 2D synthetic images (mixture of vessel-enhanced and non-enhancement), each with 55 annotated anatomical landmarks (two are landmarks for eye lenses), generated from 135 retrospectively collected head computed tomography (CT) volumetric data. Before training, dynamic random cropping was performed to mimic the varied field-size collimation in FGI procedures. Gaussian-distributed additive noise was applied to each individual image to enhance the robustness of the DL model in handling image degradation that may occur during clinical image acquisition in a clinical environment. The model was trained with 629370 synthetic images for approximately 275000 iterations and evaluated against a synthetic image test set and a clinical fluoroscopy test set. The model shows good performance in estimating in- and out-of-image landmark positions and shows feasibility to instantiate the skull shape. The model successfully detected 96.4% and 92.5% 2D and 3D landmarks, respectively, within a 10mm error on synthetic test images. It demonstrated an average of 3.6±2.3mm mean radial error and successfully detected 96.8% 2D landmarks within 10mm error on clinical fluoroscopy images. Our deep-learning model successfully localizes anatomical landmarks and estimates the gross shape of skull structures from collimated 2D projection views. This method may help identify the exposure region required for patient-specific organ dosimetry in FGIs procedures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.