Abstract

BackgroundUndetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV). Therefore, the series of RR intervals are normally carefully edited before HRV is analysed, but this is a time consuming procedure when 24-hours recordings are analysed. Alternatively, different methods can be used for automatic removal of arrhythmic beats and artefacts. This study compared common frequency domain indices of HRV when determined from manually edited and automatically filtered RR intervals.Methods and ResultsTwenty-four hours Holter recordings were available from 140 healthy subjects of age 1-75 years. An experienced technician carefully edited all recordings. Automatic filtering was performed using a recursive procedure where RR intervals were removed if they differed from the mean of the surrounding RR intervals with more than a predetermined limit (ranging from 10% to 50%). The filtering algorithm was evaluated by replacing 1% of the beats with synthesised ectopic beats. Power spectral analysis was performed before and after filtering of both the original edited data and the noisy data set. The results from the analysis using the noisy data were used to define an age-based filtering threshold. The age-based filtration was evaluated with completely unedited data, generated by removing all annotations from the series of RR intervals, and then comparing the resulting HRV indices with those obtained using edited data. The results showed equivalent results after age-based filtration of both the edited and unedited data sets, where the differences in HRV indices obtained by different preprocessing methods were small compared to the mean values within each age group.ConclusionsThe study showed that it might not be necessary to perform the time-consuming careful editing of all detected heartbeats before HRV is analysed in Holter recordings.In most subjects, it is sufficient to perform the regular editing needed for valid arrhythmia analyses, and then remove undetected ectopic beats and artefacts by age-based filtration of the series of RR intervals, particularly in subjects older than 30 years.

Highlights

  • Undetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV)

  • The study showed that it might not be necessary to perform the timeconsuming careful editing of all detected heartbeats before HRV is analysed in hour ambulatory ECG recordings (Holter) recordings

  • It is sufficient to perform the regular editing needed for valid arrhythmia analyses, and remove undetected ectopic beats and artefacts by age-based filtration of the series of RR intervals, in subjects older than 30 years

Read more

Summary

Introduction

Undetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV). The series of RR intervals are normally carefully edited before HRV is analysed, but this is a time consuming procedure when 24-hours recordings are analysed. This study compared common frequency domain indices of HRV when determined from manually edited and automatically filtered RR intervals. Arrhythmic beats and artefacts that are undetected during the ECG signal preprocessing seriously affect the power spectrum of the HRV [2,3,4,5]. Modern Holter systems include different methods to automatically remove undetected arrhythmic beats and artefacts [6,7,8]. We hypothesized that there would be no clinically relevant differences in the calculated HRV parameters, when calculated from automatically filtered RR intervals as compared to manually edited RR intervals

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.