Abstract

The paper describes a complex project of flow rate measurement applied for groundwater discharge into a tunnel, for both individual seepage points and the collection channel totalizing the flow. Various standard methods are used according to a large range of flow rate magnitudes (tipping bucket, danaid, V-shaped weir) with partial improvements and technical adaptations. Data collection is provided by individual measurement units with ethernet interface sending data to a database server through the internet. Experience of 10 years with several upgrades of either individual measurement or the electronic collection and transmission system is summarized.