Abstract

Electronic cleansing is an image post processing technique in which the tagged colonic content is subtracted from colon using CTC images. There are post processing artefacts, like: 1) soft tissue degradation; 2) incomplete cleansing; 3) misclassification of polyp due to pseudo enhanced voxels; and 4) pseudo soft tissue structures. The objective of the study was to subtract the tagged colonic content without losing the soft tissue structures. This paper proposes a novel adaptive method to solve the first three problems using a multi-step algorithm. It uses a new edge model-based method which involves colon segmentation, priori information of Hounsfield units (HU) of different colonic contents at specific tube voltages, subtracting the tagging materials, restoring the soft tissue structures based on selective HU, removing boundary between air-contrast, and applying a filter to clean minute particles due to improperly tagged endoluminal fluids which appear as noise. The main finding of the study was submerged soft tissue structures were absolutely preserved and the pseudo enhanced intensities were corrected without any artifact. The method was implemented with multithreading for parallel processing in a high performance computer. The technique was applied on a fecal tagged dataset (30 patients) where the tagging agent was not completely removed from colon. The results were then qualitatively validated by radiologists for any image processing artifacts.

Highlights

  • Computed tomography colonography (CTC) is a medical imaging and diagnosis procedure for finding the colon polyps through image processing application using primary 2D Multi Planar Reformatted (MPR) and 3D volume rendered images (Rakesh, 2011)

  • Electronic cleansing is an image post processing technique in which the tagged colonic content is subtracted from colon using CTC images

  • This paper proposes a novel adaptive method to solve the first three problems using a multi-step algorithm. It uses a new edge model-based method which involves colon segmentation, priori information of Hounsfield units (HU) of different colonic contents at specific tube voltages, subtracting the tagging materials, restoring the soft tissue structures based on selective HU, removing boundary between air-contrast, and applying a filter to clean minute particles due to improperly tagged endoluminal fluids which appear as noise

Read more

Summary

Introduction

Computed tomography colonography (CTC) is a medical imaging and diagnosis procedure for finding the colon polyps through image processing application using primary 2D Multi Planar Reformatted (MPR) and 3D volume rendered images (Rakesh, 2011). Patient is administered with oral contrast through a procedure called fecal tagging in which the stool shows homogenous attenuation coefficient (AC) when it absorbs the contrast (Figure 1b, d-e) whereas the soft tissue does not absorb (Tian, 2015) and their AC is unaltered (Figure 1b, e). IC mainly occurs in low dose CT scanning or medium dose bowel preparation which results in non-homogenous AC and demands more post processing. It leads to incomplete cleansing near air – contrast boundary (Figure 1b). The evolution of engineering solutions published so far by others in solving these problems and the inference from their work are discussed below

Objectives
Methods
Results
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.