Abstract

Automatic solutions for generating radiotherapy treatment plans using deep learning (DL) have been investigated by mimicking the voxel's dose. However, plan optimization using voxel-dose features has not been extensively studied. This study aims to investigate the efficiency of a direct optimization strategy with finite elements (FEs) after DL dose prediction for automatic intensity-modulated radiation therapy (IMRT) treatment planning. A double-UNet DL model was adapted for 220 cervical cancer patients (200 for training and 20 for testing), who underwent IMRT between 2016 and 2020 at our clinic. The model inputs were computed tomography (CT) slices, organs at risk (OARs), and planning target volumes (PTVs), and the outputs were dose distributions of uniformly generated high-dose region-controlled plans. The FEs were discretized into equal intervals of the dose prediction value within the [OARs avoid PTV(O-P)] and [body avoids OARs & PTV(B-OP)] regions in the test cohort and used to define the objectives for IMRT plan optimization. The plans were optimized using a two-step process. In the beginning, the plans of two extra cases with and without low-dose region control were compared to pursue robust and optimal dose adjustment degree pattern of FEs. In the first step, the mean dose of O-P FEs were constrained to differing degrees according to the pattern. The further the FEs from the PTV, the tighter the constraints. In the second step, the mean dose of O-P FEs from first step were constrained again but weakly and the dose of the B-OP FEs from dose prediction and PTV were tightly regulated. The dosimetric parameters of the OARs and PTV were evaluated and compared using an interstep approach. In another 10 cases, the plans optimized via the aforementioned steps (method 1) were compared with those directly generated by the double-UNet dose prediction model trained by low and high region-controlled plans (method 2). The mean differences in dose metrics between the UNet-predicted dose and the clinical plans were: 0.47Gy for bladder D50% ; 0.62Gy for rectum D50% ; 0% for small intestine V30Gy ; 1% for small intestine V40Gy ; 4% for left femoral head V30Gy ; and 6% for right femoral head V30Gy . The reductions in mean dose (p<0.001) after FE-based optimization were: 4.0, 1.9, 2.8, 5.9, and 5.7Gy for the bladder, rectum, small intestine, left femoral head, and right femoral head, respectively, with flat PTV homogeneity and conformity. Method 1 plans produced lower mean doses than those of method 2 for the bladder (0.7Gy), rectum (1.0Gy), and small intestine (0.6Gy), while maintaining PTV homogeneity and conformity. FE-based direct optimization produced lower OAR doses and adequate PTV doses after DL prediction. This solution offers rapid and automatic plan optimization without manual adjustment, particularly in low-dose regions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call