Abstract
The Oxford Rig was designed for biomechanical testing of post-mortem human knee-joint specimens during simulated flexed-knee stance, such as occurs when riding a bicycle, rising from a chair, or climbing stairs. It has been asserted, but never proven, that the movements of the ‘ankle’ and ‘hip’ assemblies of the Oxford Rig combine to allow a knee specimen its natural six degrees-of-freedom of movement (6 d.o.f.). This paper investigates this claim mathematically using the general mobility criterion for spatial linkages and the basics of screw theory. It is shown that within the physiological range of knee-joint movement and the physical construction of the Rig, the knee specimen is allowed full spatial freedom (6 d.o.f.). The general approach used in this paper could also be applied to the analysis and, in particular, to the design of other rigs used for biomechanical testing of post-mortem human joint specimens.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.