Abstract

Objective. Delineation of relevant normal tissues is a bottleneck in image-guided precision radiotherapy workflows for small animals. A deep learning (DL) model for automatic contouring using standardized 3D micro cone-beam CT (μCBCT) volumes as input is proposed, to provide a fully automatic, generalizable method for normal tissue contouring in preclinical studies. Approach. A 3D U-net was trained to contour organs in the head (whole brain, left/right brain hemisphere, left/right eye) and thorax (complete lungs, left/right lung, heart, spinal cord, thorax bone) regions. As an important preprocessing step, Hounsfield units (HUs) were converted to mass density (MD) values, to remove the energy dependency of the μCBCT scanner and improve generalizability of the DL model. Model performance was evaluated quantitatively by Dice similarity coefficient (DSC), mean surface distance (MSD), 95th percentile Hausdorff distance (HD95p), and center of mass displacement (ΔCoM). For qualitative assessment, DL-generated contours (for 40 and 80 kV images) were scored (0: unacceptable, manual re-contouring needed - 5: no adjustments needed). An uncertainty analysis using Monte Carlo dropout uncertainty was performed for delineation of the heart. Main results. The proposed DL model and accompanying preprocessing method provide high quality contours, with in general median DSC > 0.85, MSD < 0.25 mm, HD95p < 1 mm and ΔCoM < 0.5 mm. The qualitative assessment showed very few contours needed manual adaptations (40 kV: 20/155 contours, 80 kV: 3/155 contours). The uncertainty of the DL model is small (within 2%). Significance. A DL-based model dedicated to preclinical studies has been developed for multi-organ segmentation in two body sites. For the first time, a method independent of image acquisition parameters has been quantitatively evaluated, resulting in sub-millimeter performance, while qualitative assessment demonstrated the high quality of the DL-generated contours. The uncertainty analysis additionally showed that inherent model variability is low.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.