ABSTRACT: The design, construction, and evaluation of two automatic bottle sealing mechanisms for the collection of volatile organic compounds in water are described. Manually collected samples were either stored in uncapped bottles or in bottles capped with the automatic bottle sealing mechanisms. After 24 hours' storage, significant losses of volatile compounds from uncapped samples occurred even if the samples were stored at 4°C, but not for the samples capped with the automatic bottle sealing mechanisms. The mechanism for sealing the sample bottles was integrated into a commercial sampler with minor modifications to the sampler. The sampling system was then evaluated under controlled conditions to simulate actual field sampling. The results showed that the system was suitable for taking sequential discrete water samples automatically for 24 hours without significant losses of volatile organic compounds.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.