Abstract

Programmable Logic Controllers (PLCs) are industrial digital computers used as automation controllers in manufacturing processes. The Ladder language is a programming language used to develop PLC software. Our aim is to prove that a given Ladder program conforms to an expected temporal behaviour given as a timing chart, describing scenarios of execution. We translate the Ladder code and the timing chart into a program for the Why3 environment, within which the verification proceeds by generating verification conditions, to be checked valid using automated theorem provers. The ultimate goal is two-fold: first, by obtaining a complete proof, we can verify the conformance of the Ladder code with respect to the timing chart with a high degree of confidence. Second, when the proof is not fully completed, we obtain a counterexample, illustrating a possible execution scenario of the Ladder code which does not conform to the timing chart.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.