Abstract

Background[68Ga]Ga-PentixaFor is a promising radiotracer for positron emission tomography imaging of several human tumors overexpressing the chemokine receptor-4 (CXCR4). CXCR4 overexpression has been demonstrated in patients with hematologic malignancies, solid cancers, as well as cardiovascular pathologies of inflammatory origins. However, its radio synthesis is not yet fully developed in France, and existing methods do not use our type of synthesis module. Therefore, we aimed at developing a [68Ga]Ga-PentixaFor synthesis with Gaia/Luna Elysia-Raytest module to use it in clinical purpose.Results12 syntheses were carried out by varying the temperature conditions and radiolabeling times, and led to choose specific labelling conditions with the Gaia/Luna Elysia-Raytest module: 97 °C, 4 min. The mean synthesis time of the 3 validation runs under good manufacturing practice (GMP) was 24 min 27 s (± 8 s), and the mean radiochemical yield was 87.0% [standard deviation (SD) 6.67%]. Different quality control parameters were also evaluated in accordance with European Pharmacopeia: radiochemical and radionuclidic purity, pH, sterility, stability and endotoxins levels. The average radiochemical purity was 99.1% (SD 0.25%) assessed by instant thin layer chromatography and 99.8% (SD 0.092%) assessed by high pressure liquid chromatography. average [68Ge] breakthrough was 1.48 × 10–5%, under the recommended level of 0.001%. We assessed the stability of the radiotracer up to 4 h at room temperature (no augmentation of the [68Ga] chloride in the final product, i.e. radiochemical purity (RCP) > 98.5%). The endotoxins levels were < 5 EU/mL, and the pH was 6.5 (same for the three syntheses).ConclusionThe [68Ga]Ga-PentixaFor synthesis process developed on the Gaia/Luna Elysia-Raytest module has fulfilled all acceptance criteria for injectable radiopharmaceutical products regarding the European Pharmacopeia. The radiochemical purity, stability, efficacy, as well as the microbiological quality of the three GMP batches were found to be good. The robustness of the synthesis process may be suitable for multi-dose application in clinical settings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.