Abstract
[18F]fluoroestradiol ([18F]FES) is well-established PET radiotracer for diagnosing and monitoring treatment of estrogen-positive breast cancer. The radiotracer is produced via one-pot two steps synthesis using cyclic sulfate precursor and is usually purified by semi-preparative HPLC. Here we suggested simple SPE purification procedure using OASIS WAX 3cc and Sep-Pak QMA light cartridges that afforded [18F]FES in typically 15% RCY (corrected for decay) within 45 min formulated in 5% EtOH/saline. All purity parameters were well within specifications recommended in the Investigator's Brochure for [18F]Fluoroestradiol.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.