Abstract

Background and objectivesStandardization of the carotid IMT requires a reference marker in ultrasound scans. It has been shown previously that manual reference marker and manually created carotid segments are used for measuring IMT in these segments. Manual methods are tedious, time consuming, subjective, and prone to errors. Bulb edge can be considered as a reference marker for measurements of the cIMT. However, bulb edge can be difficult to locate in ultrasound scans due to: (a) low signal to noise ratio in the bulb region as compared to common carotid artery region; (b) uncertainty of bulb location in craniocaudal direction; and (c) variability in carotid bulb shape and size. This paper presents an automated system (a class of AtheroEdge™ system from AtheroPoint™, Roseville, CA, USA) for locating the bulb edge as a reference marker and further develop segmental-IMT (sIMT) which measures IMT in 10mm segments (namely: s1, s2 and s3) proximal to the bulb edge. MethodsThe patented methodology uses an integrated approach which combines carotid geometry and pixel-classification paradigms. The system first finds the bulb edge and then measures the sIMT proximal to the bulb edge. The system also estimates IMT in bulb region (bIMT). The 649 image database consists of varying plaque (light, moderate to heavy), image resolutions, shapes, sizes and ethnicity. ResultsOur results show that the IMT contributions in different carotid segments are as follows: bulb-IMT 34%, s1-IMT 29.46%, s2-IMT 11.48%, and s3-IMT 12.75%, respectively. We compare our automated results against reader's tracings demonstrating the following performance: mean lumen-intima error: 0.01235 ± 0.01224mm, mean media-adventitia error: 0.020933 ± 0.01539mm and mean IMT error: 0.01063 ± 0.0031mm. Our system's Precision of Merit is: 98.23%, coefficient of correlation between automated and Reader's IMT is: 0.998 (p-value < 0.0001). These numbers are improved compared to previous publications by Suri's group which is automated multi-resolution conventional cIMT. ConclusionsOur fully automated bulb detection system reports 92.67% precision against ideal bulb edge locations as marked by the reader in the bulb transition zone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.