Abstract

ObjectiveThe aim of this study is to present a newly developed automated method to determine radiographic measurements of hip morphology on dual-energy x-ray absorptiometry (DXA) images. The secondary aim was to compare the performance of the automated and manual measurements. Design30 DXA scans from 13-year-olds of the prospective population-based cohort study Generation R were randomly selected. The hip shape was outlined automatically using radiographic landmarks from which the acetabular depth-width ratio (ADR), acetabular index (AI), alpha angle (AA), Wiberg and lateral center edge angle (WCEA) (LCEA), extrusion index (EI), neck-shaft angle (NSA), and the triangular index (TI) were determined. Manual assessments were performed twice by two orthopedic surgeons. The agreement within and between observers and methods was visualized using Bland-Altman plots, and the reliability was studied using the intraclass correlation coefficient (ICC) with 95 % confidence intervals (CI). ResultsThe automated method was able to perform all radiographic hip morphology measurements. The intermethod reliability between the automated and manual measurements ranged from 0.57 to 0.96 and was comparable to or better than the manual interobserver reliability, except for the AI. ConclusionThis open-access, automated method allows fast and reproducible calculation of radiographic measurements of hip morphology on right hip DXA images. It is a promising tool for performing automated radiographic measurements of hip morphology in large population studies and clinical practice.