Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Wellcome Trust. Background Quantitative myocardial perfusion cardiac magnetic resonance (QP-CMR) is gaining importance in clinical practice due to the increasing availability of automated processing software. However, a significant obstacle in the widespread deployment of QP-CMR is the accurate estimation of the arterial input function (AIF), as this is precluded by the non-linear relationship between observed MR signal and the concentration of contrast agent. Modern solutions favour a dual-saturation acquisition sequence, acquiring specific low-resolution images with a short saturation time to minimise the signal saturation of the AIF. However, this approach is limited by the availability of the pulse sequence. Recently, the AI-AIF has been proposed (1), which uses an artificial intelligence (AI)-based correction of the AIF, without the need for a dual-sequence or dual-bolus acquisition. Purpose In this work, we compare QP-CMR values, quantified with the AI-AIF versus the invasive reference standard: fractional flow reserve (FFR), to identify diagnostically significant coronary artery disease (CAD), as defined by FFR < 0.80. Methods This study enrolled 18 patients (mean age 65 (± 11), 8 female) who underwent stress perfusion CMR (Philips Achieva 3T) and invasive FFR assessment of at least one coronary artery. Perfusion was quantified in a fully-automated manner with motion compensation (2) and AI-based segmentation and processing (3), using a Fermi function-constrained deconvolution. Fully automated pixelwise perfusion maps were generated, and further subdivided into 16 myocardial segments. Segments were assigned to their respective perfusion territory (4) and the QP value for a territory is given as the mean of its two lowest segments. Receiver operating characteristic (ROC) analysis was performed to identify cut-off thresholds and report the diagnostic accuracy of the proposed approach. Results The overall mean QP-CMR value was 2.29 ml/min/g (± 0.32). Figure 1 shows QP maps and FFR values for 3 example patients. The mean QP-CMR value was 2.09 ml/min/g (± 0.36) in patients with significant CAD and 2.95 ml/min/g (± 0.48) in patients without significant CAD. In total, 28 vessels underwent FFR assessment with 12 vessels in 10 patients being positive for significant CAD (FFR < 0.80). The mean QP-CMR value in FFR-positive coronary territories was 1.76 ml/min/g (± 0.37). The ROC curves are shown in Figure 2 on a per-vessel (left) and per-patient (right) level. The optimal QP threshold on a per-vessel level is 2.11 ml/min/g and on a per-patient level is 1.96 ml/min/g. Conclusion QP-CMR is feasible with the AI-AIF and does not require dual-sequence acquisition or a dual contrast injection. The QP values derived after the AI-based correction of the AIF show good agreement with FFR assessment of epicardial coronary disease. However, due to the limited sample size, further work is required to confirm these findings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call