Abstract

Accurate measurement of path length and path length changes versus momentum (M/sub 56/) are critical for maintaining minimum beam energy spread in the CEBAF (Continuous Electron Beam Accelerator Facility) accelerator at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The relative path length for each circuit of the beam (1256 m) must be equal within 1.5 degrees of 1497 MHz RF phase. A relative path length measurement is made by measuring the relative phases of RF signals from a cavity that is separately excited for each pass of a 4.2 /spl mu/s pulsed beam. This method distinguishes the path length to less than 0.5 degrees of RF (<280 /spl mu/m) and gives the direction of the path length error. The development of a VME based automated measurement system for path length and M/sub 56/ has contributed to faster machine setup time and has the potential for use as a feedback parameter for automated control.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.