Abstract

Dosimetric parameters in volumetric modulated arc therapy (VMAT), non-coplanar VMAT (NC-VMAT), and automated NC-VMAT (HyperArc, HA) were compared for patients with maxillary sinus carcinoma (MSC). Twenty HA plans were generated to deliver 70.4, 64, and 46 Gy for planning target volumes with high (PTV1), intermediate (PTV2), and low risk (PTV3), respectively. The VMAT and NC-VMAT plans were retrospectively generated using the same optimized parameters as those used in the HA plans. For PTV1, the three treatment plans provided comparable target coverages. For PTV2, the D95%, D99%, and Dmin in the HA plans (64.7±1.2, 62.7±2.1 and 54.6±6.2 Gy, respectively) were significantly higher (p<0.05) than those in the VMAT plans (64.3±1.7, 61.9±2.4 and 52.9±6.4 Gy, respectively). The NC-VMAT and HA plans provided significantly higher (p<0.05) dosimetric parameters for PTV3 than those in the VMAT plans, and D99% in the HA was significantly higher than that in the NC-VMAT plans (52.5±3.0 vs. 51.8±2.7 Gy, p<0.05). The doses to the brain and brainstem were lowest in the HA plans (p<0.05). Moreover, dosimetric parameters of the contralateral organs (lens, optic nerve, retina, and parotid) were lower in the HA plans than in the VMAT and NC-VMAT plans. The HA plans provided the best target coverage and OAR sparing compared with VMAT and NC-VMAT plans for patients with MSC.