Abstract
Screening programs using retinal photography for the detection of diabetic eye disease are being introduced in the UK and elsewhere. Automatic grading of the images is being considered by health boards so that the human grading task is reduced. Microaneurysms (MAs) are the earliest sign of this disease and so are very important for classifying whether images show signs of retinopathy. This paper describes automatic methods for MA detection and shows how image contrast normalization can improve the ability to distinguish between MAs and other dots that occur on the retina. Various methods for contrast normalization are compared. Best results were obtained with a method that uses the watershed transform to derive a region that contains no vessels or other lesions. Dots within vessels are handled successfully using a local vessel detection technique. Results are presented for detection of individual MAs and for detection of images containing MAs. Images containing MAs are detected with sensitivity 85.4% and specificity 83.1%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.