Abstract

Load curve data refers to the electric energy consumption recorded by meters at certain time intervals at delivery points or end user points, and contains vital information for day-to-day operations, system analysis, system visualization, system reliability performance, energy saving and adequacy in system planning. Unfortunately, it is unavoidable that load curves contain corrupted data and missing data due to various random failure factors in meters and transfer processes. This paper presents the B-Spline smoothing and Kernel smoothing based techniques to automatically cleanse corrupted and missing data. In implementation, a man-machine dialogue procedure is proposed to enhance the performance. The experiment results on the real British Columbia Transmission Corporation (BCTC) load curve data demonstrated the effectiveness of the presented solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.