Abstract

BackgroundEarly detection of diastolic dysfunction is crucial for patients with incipient heart failure. Although this evaluation could be performed from phase-contrast (PC) cardiovascular magnetic resonance (CMR) data, its usefulness in clinical routine is not yet established, mainly because the interpretation of such data remains mostly based on manual post-processing. Accordingly, our goal was to develop a robust process to automatically estimate velocity and flow rate-related diastolic parameters from PC-CMR data and to test the consistency of these parameters against echocardiography as well as their ability to characterize left ventricular (LV) diastolic dysfunction.ResultsWe studied 35 controls and 18 patients with severe aortic valve stenosis and preserved LV ejection fraction who had PC-CMR and Doppler echocardiography exams on the same day. PC-CMR mitral flow and myocardial velocity data were analyzed using custom software for semi-automated extraction of diastolic parameters. Inter-operator reproducibility of flow pattern segmentation and functional parameters was assessed on a sub-group of 30 subjects. The mean percentage of overlap between the transmitral flow segmentations performed by two independent operators was 99.7 ± 1.6%, resulting in a small variability (<1.96 ± 2.95%) in functional parameter measurement. For maximal myocardial longitudinal velocities, the inter-operator variability was 4.25 ± 5.89%. The MR diastolic parameters varied significantly in patients as opposed to controls (p < 0.0002). Both velocity and flow rate diastolic parameters were consistent with echocardiographic values (r > 0.71) and receiver operating characteristic (ROC) analysis revealed their ability to separate patients from controls, with sensitivity > 0.80, specificity > 0.80 and accuracy > 0.85. Slight superiority in terms of correlation with echocardiography (r = 0.81) and accuracy to detect LV abnormalities (sensitivity > 0.83, specificity > 0.91 and accuracy > 0.89) was found for the PC-CMR flow-rate related parameters.ConclusionsA fast and reproducible technique for flow and myocardial PC-CMR data analysis was successfully used on controls and patients to extract consistent velocity-related diastolic parameters, as well as flow rate-related parameters. This technique provides a valuable addition to established CMR tools in the evaluation and the management of patients with diastolic dysfunction.

Highlights

  • Detection of diastolic dysfunction is crucial for patients with incipient heart failure

  • cardiovascular magnetic resonance (CMR) is known as the modality of choice for the evaluation of global left ventricular (LV) function [20,21], systolic function and myocardial viability [22,23], Doppler echocardiography remains the clinical reference for the evaluation of diastolic dysfunction [4,24,25]

  • Our CMR longitudinal velocity was significantly reduced in patients with severe aortic valve stenosis and the resulting ratio EMR/E’MR characterized LV dysfunction with a lower sensitivity than the echocardiographic ratio, but a higher specificity and an equivalent accuracy

Read more

Summary

Introduction

Detection of diastolic dysfunction is crucial for patients with incipient heart failure. This evaluation could be performed from phase-contrast (PC) cardiovascular magnetic resonance (CMR) data, its usefulness in clinical routine is not yet established, mainly because the interpretation of such data remains mostly based on manual post-processing. Our goal was to develop a robust process to automatically estimate velocity and flow rate-related diastolic parameters from PC-CMR data and to test the consistency of these parameters against echocardiography as well as their ability to characterize left ventricular (LV) diastolic dysfunction. Altered diastolic function, which is strongly related to the quality of left ventricular (LV) filling, is a source of heart failure: it has been shown that 40 to 50% of patients suffering from heart failure have a normal LV ejection fraction while their diastolic function is impaired [1]. It has been shown that the calculated ratios E/A and E/E’, as well as DT, have a high prognostic value [4,5]

Objectives
Methods
Results
Discussion
Conclusion