Abstract

To investigate the correlation between postoperative corneal astigmatism (PCA) and values of intraoperative keratoscopy analyzed with a newly developed automated technique in patients undergoing big-bubble (BB) deep anterior lamellar keratoplasty (DALK). Photographs of keratoscope rings taken at the end of BB-DALK were analyzed using ImageJ for the calculation of "roundness" (R): values = 1 indicate a perfect circle. Pearson's correlation was used to evaluate the relationship between R and PCA that measured 1week (V1), 3months (V2), and 18months (V3), postoperatively. The area under the curve (AUC) of receiver operating characteristic (ROC) curve was used to evaluate the accuracy of R for identifying patients with PCA < 3 diopters (D). The point on the ROC curve nearest to the coordinate (0,100) was used as a cutoff to determine sensitivity and specificity. Data from 121 patients were included. The mean value of R*was 0.93 ± 0.04 (range 0.76-0.99). R showed a significant correlation with PA at V3 (R = - 0.42, P < 0.01). The ROC curve had an AUC of 0.69 (95% CI 0.59-0.79). A cutoff value of R= 0.93 had a sensitivity of 70.3% and specificity of 61.0% for identifying patients with PA < 3D at V3. This new digital analysis of keratoscope rings allows to identify with reasonably good diagnostic accuracy patients with low values of post-DALK astigmatism correctable with spectacles.