Abstract
In this paper, we present the automated diagnostic systems for Doppler ultrasound signals classification with diverse and composite features and determine their accuracies. We compared the classification accuracies of six different classifiers, namely multilayer perceptron neural network (MLP), combined neural network (CNN), mixture of experts (ME), modified mixture of experts (MME), probabilistic neural network (PNN), and support vector machine (SVM), which were trained on diverse or composite features. The present study was conducted with the purpose of answering the question of whether the automated diagnostic systems improve the capability of classification of ophthalmic arterial (OA) and internal carotid arterial (ICA) Doppler signals. Our research demonstrated that the SVM trained on composite feature and the MME trained on diverse features achieved accuracy rates which were higher than that of the other automated diagnostic systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.