Abstract

With the increasing prevalence of diabetes, annual screening for diabetic retinopathy (DR) by expert human grading of retinal images is challenging. Automated DR image assessment systems (ARIAS) may provide clinically effective and cost-effective detection of retinopathy. We aimed to determine whether ARIAS can be safely introduced into DR screening pathways to replace human graders. Observational measurement comparison study of human graders following a national screening program for DR versus ARIAS. Retinal images from 20 258 consecutive patients attending routine annual diabetic eye screening between June 1, 2012, and November 4,2013. Retinal images were manually graded following a standard national protocol for DR screening and were processed by 3 ARIAS: iGradingM, Retmarker, and EyeArt. Discrepancies between manual grades and ARIAS results were sent to a reading center for arbitration. Screening performance (sensitivity, false-positive rate) and diagnostic accuracy (95% confidence intervals of screening-performance measures) were determined. Economic analysis estimated the cost per appropriate screening outcome. Sensitivity point estimates (95% confidence intervals) of the ARIAS were as follows: EyeArt 94.7% (94.2%-95.2%) for any retinopathy, 93.8% (92.9%-94.6%) for referable retinopathy (human graded as either ungradable, maculopathy, preproliferative, or proliferative), 99.6% (97.0%-99.9%) for proliferative retinopathy; Retmarker 73.0% (72.0 %-74.0%) for any retinopathy, 85.0% (83.6%-86.2%) for referable retinopathy, 97.9% (94.9%-99.1%) for proliferative retinopathy. iGradingM classified all images as either having disease or being ungradable. EyeArt and Retmarker saved costs compared with manual grading both as a replacement for initial human grading and as a filter prior to primary human grading, although the latter approach was less cost-effective. Retmarker and EyeArt systems achieved acceptable sensitivity for referable retinopathy when compared with that of human graders and had sufficient specificity to make them cost-effective alternatives to manual grading alone. ARIAS have the potential to reduce costs in developed-world health care economies and to aid delivery of DR screening in developing or remote health care settings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.