Abstract

Background and Objective: Premature ventricular contraction (PVC) is the common arrhythmia disease, affecting thousands of individuals worldwide. However, the traditional PVC detection is cumbersome by visually inspecting electrocardiogram (ECG) signals.Methods: In this work, we specially propose an improved gated recurrent unit (IGRU) by setting a scale parameter into existing bidirectional GRU (BGRU) model for PVC signals recognition, which is used to alleviate the problem of information redundancy in BGRU. To verify the effectiveness, IGRU model will be embedded into a convolutional network frame and existing GRU and BGRU models are employed as control groups for a fair comparison.Results: The results exhibit that the model attains better model performance than control groups and several state-of-the-art algorithms with the accuracy of 98.3% and 97.9% with the MIT-BIH arrhythmia database and China Physiological Signal Challenge 2018 database. Besides, motivated from the waveform characteristics of ECG signals in PVC, the proposed model can provide certain physiological interpretability for physicians and researchers.Conclusions: To our knowledge, this is the first attempt to re-design the existing GRU network for ECG signals classification, thus exhibiting great application potentials especially in lightweight equipment such as mobile phone and camera.