Abstract

A MATLAB-based (The MathWorks, Inc, Natick, MA) computer program (the ganglion cell-inner plexiform layer [GCIPL] hemifield test) for automated detection of GCIPL thickness difference across the horizontal raphe was developed, and its glaucoma diagnostic performance was assessed. Cross-sectional study. A total of 65 eyes of normal, healthy subjects along with 162 eyes of patients with glaucoma (79 preperimetric and 83 early perimetric). Cirrus high-definition optical coherence tomography (HD-OCT) (Carl Zeiss Meditec, Dublin, CA) was used to scan all of the subjects' macular and optic discs. A positive (i.e., "outside normal limits") GCIPL hemifield test result was declared if the following 3 conditions were all met: (1) The reference line (a horizontal line dividing the superior and inferior hemifields) is continuously detected for longer than one-half of the distance from the temporal inner elliptical annulus to the outer elliptical annulus; (2) the average GCIPL thickness difference within 10 pixels of the reference line, both above and below, is ≥5 μm; and (3) the average RGB color ranges of the 10 pixels above and below the reference line display blue in 1 hemifield and red/yellow/white in the other hemifield. Comparison of diagnostic ability using the areas under the receiver operating characteristic curves (AUCs). A positive GCIPL hemifield test result was observed more frequently in the glaucomatous eyes (74/79 preperimetric, 78/83 early perimetric) than in the normal eyes (1/65). In the preperimetric group, the AUC of the GCIPL hemifield test (0.967; sensitivity 94.94%, specificity 98.46%) was greater than that of the minimum GCIPL thickness (0.933), the inferotemporal GCIPL thickness (0.907), and the average GCIPL thickness (0.899) (P=0.09, 0.06, and 0.03, respectively). In the early perimetric group, the AUC of the GCIPL hemifield test (0.962; sensitivity 93.98%, specificity 96.46%) was greater than that of the inferotemporal GCIPL thickness (0.938), the minimum GCIPL thickness (0.919), and the average GCIPL thickness (0.912) (P=0.38, 0.17, and 0.11, respectively). For discrimination of early glaucomatous structural loss, most notably in preperimetric glaucoma cases, identification of the GCIPL thickness difference across the horizontal raphe was effective.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.