Abstract

Application of artificial intelligence (AI) for automated contouring of tumor volumes and organs at risk (OARs) for radiotherapy of nasopharyngeal carcinoma (NPC) leads to improved contouring accuracy and efficiency. However, few studies have involved the automated contouring of gross tumor volume of cervical lymph nodes (GTVn) and clinical target volumes (CTVs). In this work, we proposed an AI automated contouring tool for GTVn and CTVs for radiotherapy of NPC on the plain scans of planning compute tomography (CT). In this retrospective study, plain scan datasets of planning CT covering the nasopharynx and neck from 139 patients with NPC between March 2022 and December 2022 were collected and divided into training, validation, and testing cohorts of 95, 24, and 20 patients, respectively. Ground truth contours of primary gross tumor volume (GTVp), GTVn (divided into GTVn_L in left neck and GTVn_R in right neck), CTVs (including high risk CTV1 contains GTVp and low risk CTV2 contains GTVp and cervical nodal levels) and OARs were delineated and were defined by consensus of two experts. We first proposed a three-dimensional (3D) U-net using GTVp and OARs as experience constrains to guide the automated delineation of GTVn and CTVs. The average Dice similarity coefficient (DSC) and average surface distance (ASD) were used to quantify the performance of the AI tool. Next, five prospective patients were enrolled for clinical evaluation of our AI tool. DSC between automated contours and radiation oncologist-revised contours and time consuming of the revision were record. Clinical characteristics of 139 retrospective and 5 prospective patients are list in Table 1. In the independent testing set of 20 patients, our AI tool showed high performance in GTVn and CTVs contouring when compared with the ground truth contours. The mean DSC were 0.73 ± 0.07, 0.74 ± 0.05, 0.93 ± 0.03, and 0.88 ± 0.03, and the mean ASD were 1.01 ± 0.43 mm, 1.14 ± 0.61 mm, 0.51 ± 0.13 mm, 1.17 ± 0.43 mm for GTVn_L, GTVn_R, CTV1 and CTV2, respectively. In the five prospective patients, mean DSC were 0.74 ± 0.07, 0.74 ± 0.10, 0.95 ± 0.01 and 0.89 ± 0.04, respectively. The median time consuming for GTVn and CTVs revision was 2minutes and 10 seconds (range, 1 minutes to 3 minutes). The proposed AI tool integrating clinical experience as constrains showed high accuracy for contouring GTVn and CTVs of NPC. With the assistance of AI contours, contouring efficiency could be probably increased, which is promising in online adaptive radiotherapy of NPC.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call