Abstract
BackgroundMagnetic resonance (MR) T2 and T2* mapping sequences allow in vivo quantification of biochemical characteristics within joint cartilage of relevance to clinical assessment of conditions such as hip osteoarthritis (OA). PurposeTo evaluate an automated immediate reliability analysis of T2 and T2* mapping from MR examinations of hip joint cartilage using a bone and cartilage segmentation pipeline based around focused shape modelling. Study typeTechnical validation. Subjects17 asymptomatic volunteers (M: F 7:10, aged 22–47 years, mass 50–90 kg, height 163-189 cm) underwent unilateral hip joint MR examinations. Automated analysis of cartilage T2 and T2* data immediate reliability was evaluated in 9 subjects (M: F 4: 5) for each sequence. Field strength/sequenceA 3 T MR system with a body matrix flex-coil was used to acquire images with the following sequences: T2 weighted 3D-trueFast Imaging with Steady-State Precession (water excitation; 10.18 ms repetition time (TR); 4.3 ms echo time (TE); Voxel Size (VS): 0.625 × 0.625 × 0.65 mm; 160 mm field of view (FOV); Flip Angle (FA): 30 degrees; Pixel Bandwidth (PB): 140 Hz/pixel); a multi-echo spin echo (MESE) T2 mapping sequence (TR/TE: 2080/18–90 ms (5 echoes); VS: 4 × 0.78 × 0.78 mm; FOV: 200 mm; FA: 180 degrees; PB: 230 Hz/pixel) and a MESE T2* mapping sequence (TR/TE: 873/3.82–19.1 ms (5 echoes); VS: 3 × 0.625 × 0.625 mm; FOV: 160 mm; FA: 25 degrees; PB: 250 Hz/pixel). AssessmentAutomated cartilage segmentation and quantitative analysis provided T2 and T2* data from test-retest MR examinations to assess immediate reliability. Statistical testsCoefficient of variation (CV) and intraclass correlations (ICC2, 1) to analyse automated T2 and T2* mapping reliability focusing on the clinically important superior cartilage regions of the hip joint. ResultsComparisons between test-retest T2 and (T2*) data revealed mean CV's of 3.385% (1.25%), mean ICC2, 1′s of 0.871 (0.984) and median mean differences of −1.139ms (+0.195ms). ConclusionThe T2 and T2* times from automated analyses of hip cartilage from test-retest MR examinations had high (T2) and excellent (T2*) immediate reliability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.