Abstract

Background[18F]PSMA-1007, a positron emission tomography (PET) tracer, specifically targets prostate-specific membrane antigen (PSMA), which is highly expressed in prostate cancer. PSMA-PET is effective especially for regional detection of biochemical recurrence, which significantly affects patient management. Herein, we established and optimized a one-step radiolabeling protocol to separate and purify [18F]PSMA-1007 with a CFN-MPS200 synthesizer for clinical application.ResultsA dedicated single use cassette and synthesis program for [18F]PSMA-1007 was generated using a single-step method for direct precursor radiolabeling. In the cassette, three tube types (fluoro-elastomer, PharMed® BPT, silicone) and two different precursor salts (trifluoroacetic acid or acetic acid) were compared for optimization. Furthermore, three-lot tests were performed under optimized conditions for quality confirmation. Activity yields and mean radiochemical purity of [18F]PSMA-1007 were > 5000 MBq and 95%, respectively, at the end of synthesis, and the decay-corrected mean radiochemical yield from all three cassettes was approximately 40% using a trifluoroacetic acid salt precursor. Fluoro-elastomer tubings significantly increased the amount of non-radioactive PSMA-1007 (8.5 ± 3.1 μg/mL) compared to those with other tubings (0.3 μg/mL). This reduced the molar activity of [18F]PSMA-1007 synthesized in the cassette assembled by fluoro-elastomer tubings (46 GBq/μmol) compared to that with PharMed® BPT and silicone tubings (1184 and 1411 GBq/μmol, respectively). Residual tetrabutylammonium, acetonitrile, and dimethyl sulfoxide levels were < 2.6 μg/mL, < 8 ppm, and < 11 ppm, respectively, and ethanol content was 8.0–8.1% in all three cassettes and two different salts. Higher activity yields, radiochemical purities, and decay-corrected radiochemical yields were obtained using an acetic acid salt precursor rather than a trifluoroacetic acid salt precursor (7906 ± 1216 MBq, 97% ± 0%, and 56% ± 4%). In the three-lot tests under conditions optimized with silicone cassettes and acetic acid salt precursor, all quality items passed the specifications required for human use.ConclusionsWe successfully automated the production of [18F]PSMA-1007 for clinical use and optimized synthesis procedures with a CFN-MPS200 synthesizer using a silicone cassette and acetic acid salt precursor. Cassette availability will facilitate a wide spread use of [18F]PSMA-1007-PET, leading to an effective prostate cancer management.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.