Abstract

IntroductionWe performed autologous rectus abdominis fascia sling surgery using Advantage™ following an unsuccessful synthetic midurethral sling.Case presentationAt the age of 76 years, the patient experienced stress urinary incontinence recurrence. A 1‐h pad test resulted in 259 g of leakage. A pressure flow study verified urine leakage while coughing and straining without detrusor overactivity. Abdominal leak point pressure was 10 cmH2O. Autologous rectus abdominis fascia sling surgery was performed using Advantage™. One month postoperatively, a 1‐h pad test resulted in 0 g of leakage.ConclusionWe believe that this method will allow the fascia sling procedure to be performed reliably even if one is unfamiliar with conventional autologous rectus abdominis fascia sling surgery.