Abstract

We would like to thank the reviewers for their insightful comments. In our experience, we have reported low rates of pseudoaneurysm (PA) and urine leak after robotic partial nephrectomy utilizing the early unclamping (EU) technique. We agree that good surgical technique, experience of the surgeon and team, and elimination of bolsters are contributing factors that minimize complications. However in our opinion, the EU technique as described is the main difference here, not surgeon experience. The other series of partial nephrectomy discussed in our manuscript come from very accomplished surgeons, yet PA and urine leak still occurred, perhaps due to technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.