Abstract

BackgroundAuditory neuropathy spectrum disorder (ANSD) is characterized by normal OHCs function as shown by intact cochlear microphonics (CMs) and/or otoacoustic emissions (OAEs); absent or grossly abnormal auditory brainstem responses (ABRs) and absent middle ear muscle reflexes. This study is designed to address whether the input/output function of distortion product OAEs (DPOAEs I/O) in ANSD patients is similar or different from normal hearing subjects. This work included 2 groups: control group (GI) composed of 20 normal hearing subjects and study group (GII) consisted of 20 patients with ANSD. All cases were subjected to basic audiological evaluation, DPOAEs I/O function recorded at four frequencies of 2f1-f2 and 5 intensity levels of L1 and L2.ResultsDPOAEs amplitudes were significantly higher in ANSD group when compared with control. The pattern of DPOAEs I/O function was different in ANSD and it was dependent on the frequency and intensity of the stimulus.ConclusionsDespite normal DPOAEs recordings in ANSD patients, their amplitudes and DP I/O function are different from that of normal hearing subjects. This finding suggested different OHC pattern of activity in ANSD patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call