Abstract

An analysis is presented of the audiograms, obtained using Telephonics TDH39 headphones (Huntington, NY), of 80 men claiming compensation for noise-induced hearing loss (NIHL) sustained during military service. A comparison with an independent database of audiograms collected using other headphones suggested that no adjustment was needed to the hearing threshold levels (HTLs) at 6 kHz to allow for the use of TDH39 headphones. The method of Moore [(2020). J. Acoust. Soc. Am. 148, 884-894] for diagnosing military noise-induced hearing loss (M-NIHL) gave a positive diagnosis for 92.5% of right ears and 97.5% of left ears. The mean HTLs were maximal and similar at 4, 6, and 8 kHz but with considerable individual variability. A comparison with age-expected HTLs showed that M-NIHL was typically greatest at 3, 4, 6, or 8 kHz but with considerable individual variability. M-NIHL values were positive from 0.5 to 8 kHz. The HTLs were significantly higher for the left than for the right ears, but the asymmetry varied across individuals and could usually be ascribed to specific features of the noise exposure. The asymmetry existed over the range from 0.5 to 8 kHz, supporting the idea that M-NIHL occurs over a wide frequency range. Tinnitus was reported by 76 of the 80 men.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call